Showing results: 16 - 30 of 209 items found.
-
Axiomtek Co., Ltd.
Axiomtek’s DIN-rail fanless embedded systems are suitable for intelligent computing and communication solutions in mission critical environments, such as power plant automation and facility monitoring systems. Axiomtek’s DIN-rail fanless embedded PCs are rugged and have passed heavy industrial EMI/EMS (Electro-Magnetic Susceptibility/ Electro-Magnetic Interference) tests for reliability in hazardous environments.
-
PDS200 -
Doble Engineering
The Doble PDS200 is a combination survey tool that uses radio frequency interference and electromagnetic interference diagnostics to find signs of partial discharge.This hand-held instrument is an ideal tool for a condition based maintenance program, allowing you to quickly find insulation defects in motors, generators, transformers, cable terminations and additional substation components.
-
The Rotation Link SAS
Fiber Optic Rotary Joints ensure flawless high-speed data transmission even in environments with strong electromagnetic interference. They are a maintenance-free alternative that eliminates friction and/or heating between rotating and stationary components.
-
EMCTEST
The LISN (Line Impedance Stabilization Network) or AMNs (Artificial Mains Networks) is a device to create a known impedance on power lines of electrical equipment during electromagnetic interference testing. Frequency range: 150kHz a 30MHz
-
M7 -
Seismic Source Co.
*Dual independent Accelerometers for Quality Assurance*Protected against electromagnetic interference (EMI)*Protected against moisture*Input polarity protected*Output short circuit protected*Withstands up to 2000 g's without damage
-
410104773 -
Virginia Panel Corporation
The adaptable G10x ITA integrates a wide variety of I/O options in various module configurations that allow engagement of up to 3,200 signal contacts. The G10x ITA has a removable backshell that also reduces electromagnetic interference.
-
410104769 -
Virginia Panel Corporation
The adaptable G6x ITA integrates a wide variety of I/O options in various module configurations that allow engagement of up to 1,920 signal contacts. The G6x ITA has a removable backshell that also reduces electromagnetic interference.
-
410128102 -
Virginia Panel Corporation
The i1 EMI has many of the standard features of the i1, in addition to Electro-Magnetic Interference (EMI) protection. The EMI shielding effect on the i1 EMI ITA is provided by the stainless steel fibers in the removable plastic cover and threaded metal coupling adapter.
-
Dayton T. Brown, Inc.
EMI/EMC testing can reliably predict product performance in any electromagnetic environment. Testing can also determine the possibility of interference with other equipment, possibly degrading performance. Testing may be required in order to comply with regulations or for informational and product improvement purposes.
-
LF1 set -
Langer EMV-Technik GmbH
The LF1 near-field probe set consists of 4 shielded near-field probes used during the development process for emission measurement of longwave, medium wave, and shortwave frequencies on electronic devices. The probe heads of the LF1 set are designed for incremental detection of sources of electromagnetic interference on assemblies. First, the electromagnetic interference of the assembly is detected by the LF-R 400 probe from up to 10 cm. Then probes with higher resolution like the LF-B 3, LF-U 5 and LF-U 2.5 are used to more precisely detect any source of interference. The probe heads are designed for taking measurements at single pins and larger components. Near-field probes are small and handy. They have a current attenuating sheath and, therefore, are electrically shielded. They can be connected to a spectrum analyzer or an oscilloscope with a 50 Ω input. The H-field probes do not have an internal terminating resistance of 50 Ω.
-
310123102 -
Virginia Panel Corporation
Includes all of the standard features of the iCon, in addition to Electro-Magnetic Interference (EMI) protection. An earth ground terminal is included on the and a "mate first, break last" feature connects the earth ground circuit. The earth ground terminal on the strain relief prevents user shock and injury.
-
M40/M58 Series -
Smiths Interconnect
M40 and M58 series are qualified for heavy drive and high power applications in mechanical engineering, tooling machines, robotics, mechatronics, printing, packaging, conveyors and marine. Both series features outstanding protection against electromagnetic interference through a full 360° screen shielding.
-
National Technical Systems
At NTS, our experience encompasses more than 50 years of electromagnetic compatibility testing for clients in the aerospace, aviation and other related industries. We maintain fully equipped electromagnetic interference testing facilities in Illinois, Arizona, California, Massachusetts, Texas and New Jersey. With the combined expertise of our team, it’s easy to identify the regulatory challenges your organization faces, and develop a comprehensive testing program that ensures your challenges are met.
-
Bourns
Bourns Miltilayer chip inductors offer high frequency, nickel barrier, monolithic construction for high reliability, and magnetically shielded construction providing low radiation. They are well-suited for DC-DC converters, and prevention of electromagnetic interference to signals on the secondary side of electronic equipment, among many applications.
-
Holland Shielding Systems B.V.
Electromagnetic fields cause interference in electronic devices and may affect the health of people close to where the fields are generated. It is important to recognize this at an early stage in a construction process, for instance at a future construction location or while construction is already underway, so that budgets are not exceeded. By means of field-strength measurements one can chart the existing electromagnetic fields and radiation emitted by GSM, UMTS antennas and transformer spaces, to mention a few examples. These measurements can help determine the best location in the new building for rooms where sensitive measurements are to take place, e.g. in hospitals or nano laboratories. And last but not least, field-strength measurements can detect sources of interference and can be part of a scheduled check of existing screened spaces and Faraday cages.